Send Message
Shenzhen Zhong Jian South Environment Co., Ltd.
Shenzhen Zhong Jian South Environment Co., Ltd.
products
Home /

products

2X4 2X2 FFU Fan Filter Unit Air Purification Equipment For Cleanroom

Product Details

Place of Origin: China

Brand Name: ZJNF

Certification: CE

Model Number: FFU 2X2

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: negotiate

Packaging Details: plywood/wooden package

Delivery Time: 10 days

Payment Terms: tt lc PayPal credit card

Get Best Price
Contact Now
Specifications
Highlight:

FFU Fan Filter Unit 2X2

,

2X2 Cleanroom fan filter unit

,

1175mm FFU Fan Filter Unit

Frame Material:
Aluminum/Stainless Steel
Air Flow:
1000-1100 M³/h
HEPA Size:
1170*570*69 Mm
FFU Size:
1175*575*320 Mm
Efficiency:
99.99% H14
Voltage:
110V/120V 50HZ/60HZ
Frame Material:
Aluminum/Stainless Steel
Air Flow:
1000-1100 M³/h
HEPA Size:
1170*570*69 Mm
FFU Size:
1175*575*320 Mm
Efficiency:
99.99% H14
Voltage:
110V/120V 50HZ/60HZ
Description
2X4 2X2 FFU Fan Filter Unit Air Purification Equipment For Cleanroom

Custom FFU Fan Filter Unit For Electronics Manufacturing Pharmaceuticals Biotechnology

 

Features

 

FFU stands for Fan Filter Unit, which is a type of air filtration system used in cleanroom environments to filter and circulate air.

The purpose of an FFU is to provide a continuous supply of clean air to a cleanroom or other controlled environment.

The unit typically consists of a fan, a filter, and a housing.

 

Application

 

FFUs are commonly used in cleanrooms, which are used in industries such as electronics manufacturing, pharmaceuticals, and biotechnology, where it is critical to maintain a controlled environment free from contaminants.

They are also used in laboratories and other facilities where the control of airborne particles is important.

 

Besides, we are mainly engaged in Designing, Manufacturing, Testing & Verification, Manufacturing Processes and Quality Control, Engineering & Installation, and After-Sale Service of clean rooms and are devoted to controlling and treatment of air PM2.5, formaldehyde, benzene, VOC, and other toxic and hazardous substances.

 

Technical Data

 

Model FFU 2X2 FFU 3X2 FFU 4X2 FFU 4X4
FFU Size 575*575*320mm 875*575*320mm 1175*575*320mm 1175*1175*370mm
Filter Size 570*570*69mm 870*570*69mm 1170*570*69mm 1170*1170*69mm

Air Flow

400-600 m³/h 800-900 m³/h 1000-1100 m³/h 1600-1700 m³/h
Speed Control 3 Gears
Voltage 110V/120V   50HZ/60HZ  
Efficiency 99.99% @ 0.3um
Material

SUS304/201 Stainless Steel/Aluminum Zinc Coated Sheet

Weight 16KG 20KG 21KG 45KG

 

 

2X4 2X2 FFU Fan Filter Unit Air Purification Equipment For Cleanroom 0

Main Components of an FFU

  1. Housing/Frame:

    • Material: Typically made of stainless steel, aluminum, or galvanized steel to provide durability and resist corrosion.
    • Design: Lightweight and compact to allow easy installation in cleanroom ceilings or workstations.
  2. Fan Unit:

    • Type: Usually consists of a centrifugal or axial fan.
    • Purpose: Draws in ambient air and pushes it through the filter at a controlled velocity.
    • Features: Often equipped with speed controls to adjust airflow according to cleanroom requirements.
  3. Air Filters:

    • Pre-Filter: Captures larger particles to extend the life of the main filter.
    • HEPA or ULPA Filter: Removes fine particles, including microbes and contaminants, ensuring a clean airflow.
      • HEPA Filter Efficiency: Captures particles ≥ 0.3 microns with 99.97% efficiency.
      • ULPA Filter Efficiency: Captures particles ≥ 0.12 microns with 99.999% efficiency.
  4. Motor:

    • Type: Often a high-efficiency, low-noise motor.
    • Drive Mechanism: Direct-drive or belt-driven.
    • Features: Designed to operate continuously with minimal energy consumption and reduced vibrations.
  5. Air Distribution System:

    • Design: Incorporates baffles or diffusers to ensure uniform air distribution across the filter.
    • Purpose: Maintains laminar airflow to minimize turbulence.
  6. Control System:

    • Includes controls for fan speed, monitoring airflow, and filter status.
    • Advanced units may feature IoT connectivity for remote monitoring and control.
  7. Vibration Dampeners:

    • Installed to minimize vibrations from the fan and motor, ensuring consistent airflow and quiet operation.
  8. Sealing Mechanism:

    • Gaskets or gel seals around the filter to prevent air leaks and ensure all air passes through the filter.

Typical FFU Design Process

  1. Air Intake: Air is drawn in from the surrounding environment through the pre-filter.
  2. Filtration: The pre-filter removes larger particles, while the HEPA or ULPA filter captures fine particles, microbes, and contaminants.
  3. Air Delivery: The filtered air is pushed out uniformly, maintaining laminar flow for a clean environment.

Applications

  • Cleanrooms (pharmaceuticals, semiconductors, biotechnology).
  • Medical facilities.
  • Laboratories.
  • Food processing plants.

 