Place of Origin: China

Brand Name: ZJNF

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: negotiate

Packaging Details: plywood/wooden package

Delivery Time: 18days

Payment Terms: tt lc PayPal credit card

Get Best Price
Contact Now
Specifications
Highlight:

Modular Clean Room With Ceiling Ffu

,

Dust Free Working Modular Clean Room

Overall Dimension:
Customized
Body Material:
Cold-roll Steel /Stainless Steel
Door Material:
Stainless Steel
Filter Efficiency:
99.99%
Air Exchange Rate:
100,000-grade 10-15 Times/hour
Temperature:
24 C–26 C In Summer; 20 To 22 DEG C In Win
Material:
Stainless Steel,Stailess Steel SUS304/201/Q195 /galvanized Sheet,sandwich Panel,fire-proof),laminated Board(scratch-proof
Application:
100 Lab / Laboratory Clean Room,Pharmaceutical,Chemical Lab,Electronic Plant,Hospital
Type:
Clean Room Booth,Modular Designs,cleanroom
Usage:
Air Purification System,Pharmaceutical Factory Or Laboratory,Dust Free Working For Lcd Glass Oca Laminating,Laborotory,clean Requirement
Overall Dimension:
Customized
Body Material:
Cold-roll Steel /Stainless Steel
Door Material:
Stainless Steel
Filter Efficiency:
99.99%
Air Exchange Rate:
100,000-grade 10-15 Times/hour
Temperature:
24 C–26 C In Summer; 20 To 22 DEG C In Win
Material:
Stainless Steel,Stailess Steel SUS304/201/Q195 /galvanized Sheet,sandwich Panel,fire-proof),laminated Board(scratch-proof
Application:
100 Lab / Laboratory Clean Room,Pharmaceutical,Chemical Lab,Electronic Plant,Hospital
Type:
Clean Room Booth,Modular Designs,cleanroom
Usage:
Air Purification System,Pharmaceutical Factory Or Laboratory,Dust Free Working For Lcd Glass Oca Laminating,Laborotory,clean Requirement
Description
Modular Clean Room With Ceiling Ffu Air Condition Filtration System For Unidirectional Airflow System Dust Free Working

Custom Cleaning Level Class Modular Cleanroom With Ceiling FFU Air Condition Filtration System

 

Key Characteristics of Cleanrooms

  1. Controlled Air Quality:

    • Airborne particle levels are strictly regulated based on cleanroom classification standards (e.g., ISO 14644 or Federal Standard 209E).
    • HEPA or ULPA filters are commonly used to remove particles as small as 0.3 microns or smaller.
  2. Positive Air Pressure:

    • Cleanrooms often maintain higher air pressure inside to prevent unfiltered air from entering when doors are opened.
  3. Temperature and Humidity Control:

    • Precise control of temperature (typically 20–22°C) and relative humidity (30–60%) to ensure optimal conditions for sensitive processes and equipment.
  4. Airflow System:

    • Laminar airflow (unidirectional) or turbulent airflow systems maintain cleanliness by continuously replacing and filtering air.
    • High air exchange rates, typically 10–600 air changes per hour, depending on the cleanroom classification.
  5. Surface Materials:

    • Interior surfaces, including walls, floors, and ceilings, are smooth, non-porous, and easy to clean to minimize particle accumulation.
    • Common materials include epoxy, stainless steel, or special-grade plastics.
  6. Personnel Protocols:

    • Workers are required to wear specialized clothing, such as cleanroom suits, gloves, masks, and booties, to minimize contamination from skin or clothing particles.
    • Strict entry and exit protocols, often through airlocks or cleanroom pass boxes.
  7. Classification Standards:

    • Cleanrooms are categorized by the allowable number of particles per cubic meter of air. For example:
      • ISO Class 1: Strictest (least particles allowed)
      • ISO Class 9: Least strict (most particles allowed)
  8. Monitoring Systems:

    • Continuous monitoring of particle levels, airflow, pressure differentials, and environmental conditions to ensure compliance with cleanroom standards.

Applications of Cleanrooms

  • Pharmaceuticals and Biotechnology: To prevent microbial contamination during drug production.
  • Semiconductor Manufacturing: To avoid defects caused by dust or other particles on microchips.
  • Aerospace: For assembling sensitive equipment like satellites or spacecraft.
  • Medical Device Manufacturing: To ensure sterility and compliance with health regulations.

Advantages of Cleanrooms

  • Enhanced product quality and consistency.
  • Compliance with regulatory standards in critical industries.
  • Protection of sensitive processes and equipment from contamination.

Cleanrooms are a cornerstone of modern high-tech manufacturing and research, ensuring optimal conditions for innovation and safety.

 

Technical Data

 

Cleanliness Level Maximum Allowable Dust Number/Cubic Meter Maximum Allowable Number of Microorganism
/ ≥0.5um ≥5um Airborne Microbe/Cubic Meter Settling Microbe Number/Vessel·30min
100 3500 0

5

1
10000 350000 2000 100 3
100000 3500000 20000 500 10
300000 10500000 60000 / 15

 